FR+L UNIT

FR+L 1/4″    042

More informations in pdf : FR+L O42

  • Unit consisting of Filter regulator + Lubricator
  • Bowl available in three configurations: transparent ( TT), transparent with outer bowl guard (PE) and short transparent version (TC).
  • Can be wall mounted using the relative holes or on brackets.
  • Pressure ranges: 0-4 Bar, 0-8 Bar (standard), 0-12,5 Bar0-0,4 MPa, 0-0,8 MPa (standard), 0-1,25 MPa
  • Maximum operating pressure: 16,0 Bar (1,6 MPa).
  • Filtering degree: 5 micron and 20 micron (standard)
  • Integrated manual and semiautomatic condensate drainage (SS) or SA and SAD automatic versions.
  • Maximum ambient temperature (at 10Bar) 50°C ( 122°F)
  • Reference flow rate (P= 6,3 Bar Δp= 1 Bar) : 750 Nl/min
  • Weight: 0,32 Kg.
  • Max. torque inserts G ¼ IN e OUT: 25 Nm
  • Product complies with Directive 2002/95/CE ( RoHS)

——————————————————————————————————————-

FR+L 3/8″    050   -   FR+L 1/2″    052

More informations in pdf : FR+L 3-8

  • Unit available in two different versions: 3/8 line 050 and ½ line 052.
  • The set pressure is kept stable regardless of upstream variations
  • Downstream overpressures quickly eliminated.
  • Quick bowl connection by means of the safety ring mechanism.
  • Can be wall mounted using the relative holes or on bracket.
  • Pressure ranges: 0-4 Bar, 0-8 Bar (standard), 0-12,5 Bar, 0-0,4 MPa, 0-0,8 MPa (standard), 0-1,25 MPa
  • Maximum operating pressure: 12,5 Bar (1,25 MPa).
  • Filtering degree: 5 micron and 20 micron (standard)
  • Integrated manual and semiautomatic condensate drainage (SS) or SA and SAD automatic versions.
  • Maximum ambient temperature (at 10Bar) 50°C ( 122°F)
  • Reference flow rate (P= 6,3 Bar Δp= 1 Bar): 1500 Nl/min
  • Weight: 0,70 Kg.
  • Max. torque inserts G 3/8 IN e OUT: 60 Nm
  • Max. torque inserts G ½ IN e OUT: 80 Nm
  • Product complies with Directive 2002/95/CE ( RoHS)

——————————————————————————————————————-

FR+L 1/2″     075

More informations in pdf : FR+L 1-2

  • The set pressure is kept stable regardless of upstream variations
  • Downstream overpressures quickly eliminated.
  • Quick bowl connection by means of the safety ring mechanism.
  • Can be wall mounted using the relative holes or on bracket.
  • Pressure ranges: 0-4 Bar, 0-8 Bar (standard), 0-12,5 Bar, 0-0,4 MPa, 0-0,8 MPa (standard), 0-1,25 MPa
  • Maximum operating pressure: 12,5 Bar (1,25 MPa).
  • Filtering degree: 5 micron and 20 micron (standard)
  • Integrated manual and semiautomatic condensate drainage (SS) or SA and SAD automatic versions.
  • Maximum ambient temperature (at 10Bar) 50°C ( 122°F)
  • Reference flow rate (P= 6,3 Bar Δp= 1 Bar) : 2200 Nl/min
  • Weight: 0,94 Kg.
  • Max. torque inserts G ½ IN e OUT: 80 Nm
  • Product complies with Directive 2002/95/CE ( RoHS)

——————————————————————————————————————-

FR+L 1″    095

More informations in pdf : FR+L 1

  • High flow rate with load losses.
  • The set pressure is kept stable regardless of upstream variations
  • Downstream overpressures quickly eliminated.
  • Quick bowl connection by means of the safety ring mechanism.
  • Can be wall mounted using the relative brackets.
  • Pressure ranges: 0-4 Bar, 0-8 Bar (standard), 0-12,5 Bar, 0-0,4 MPa, 0-0,8 MPa (standard), 0-1,25 MPa
  • Maximum operating pressure: 12,5 Bar (1,25 MPa).
  • Filtering degree: 5 micron and 20 micron (standard)
  • Integrated manual and semiautomatic condensate drainage (SS) or SA and SAD automatic versions.
  • Maximum ambient temperature (at 10Bar) 50°C ( 122°F)
  • Reference flow rate (P= 6,3 Bar Δp= 1 Bar) : 8.000 Nl/min
  • Weight: 3,37 Kg.
  • Max. torque inserts G 1” IN e OUT: 80 Nm